A |
B |
C |
D |
E |
F |
G |
H |
J |
K |
L |
M |
N |
O |
FLOOR
PROTECTOR
NOTE
NUMBER |
WATER
HEATING
OPTIONAL
EXTRA |
| Royale AG |
| with flue shield |
100 |
200 |
300 |
110 |
50 |
200 |
520 |
330 |
810 |
930 |
1200 |
1030 |
730 |
500 |
3 |
|
| no flue shield |
300 |
200 |
300 |
110 |
100 |
400 |
520 |
400 |
810 |
1130 |
1280 |
1090 |
730 |
500 |
3 |
| Lady Kitchener AG |
| pedestal & drawer base |
100 |
385 |
470 |
100 |
150 |
270 |
640 |
450 |
710 |
1220 |
1590 |
1340 |
950 |
540 |
2 |
3 kw
wetback
|
| leg base |
100 |
385 |
300 |
100 |
150 |
270 |
640 |
450 |
710 |
1050 |
1420 |
1200 |
780 |
540 |
2 |
| Lady Kitchener Urban |
| pedestal & drawer base |
100 |
240 |
300 |
100 |
95 |
270 |
495 |
395 |
710 |
1050 |
1365 |
1145 |
780 |
540 |
2 |
3 kw
wetback
|
| leg base |
100 |
240 |
300 |
100 |
95 |
270 |
495 |
395 |
710 |
1050 |
1365 |
1145 |
780 |
540 |
3 |
| Contessa AG *Clearances A,F & K: can be reduced by 30mm provided a Contessa Cooktop grill is fitted to the fire |
| pedestal & drawer base |
130* |
280 |
420 |
110 |
100 |
260* |
600 |
420 |
860 |
1055* |
1380 |
1200 |
795 |
600 |
2 |
3 kw
wetback |
| leg base |
130* |
280 |
350 |
110 |
100 |
260* |
600 |
420 |
860 |
985* |
1310 |
1130 |
725 |
600 |
2 |
| Contessa Urban *C;earamces A,F & K: can be reduced by 30mm provided a Contessa Cooktop Grill is fitted to the fire |
| pedestal & drawer base |
130* |
280 |
420 |
110 |
100 |
260* |
600 |
420 |
860 |
1055* |
1380 |
1200 |
795 |
600 |
2 |
|
| leg base |
130* |
280 |
350 |
110 |
100 |
260* |
600 |
420 |
860 |
985* |
1310 |
1130 |
725 |
600 |
3 |
| Viking AG |
| Drawer Base |
100 |
320 |
300 |
120 |
50 |
260 |
590 |
350 |
780 |
1040 |
1280 |
1060 |
780 |
410 |
3 |
3 kw wetback |
| Bronte Top Outlet AG |
| pedestal & drawer base |
100 |
250 |
435 |
100 |
50 |
230 |
555 |
355 |
810 |
1000 |
1295 |
1170 |
770 |
630 |
2 |
|
| leg base |
100 |
250 |
300 |
100 |
50 |
230 |
555 |
355 |
810 |
865 |
1210 |
1080 |
635 |
630 |
2 |
| Bronte Rear Outlet AG > into chimney cavity - can only be installed with wet back |
| pedestal & drawer base |
100 |
245 |
470 |
100 |
n/a |
n/a |
550 |
n/a |
810 |
1035 |
n/a |
n/a |
n/a |
630 |
2 |
3 kw
wetback
|
| leg base |
100 |
245 |
405 |
100 |
n/a |
n/a |
550 |
n/a |
810 |
970 |
n/a |
n/a |
n/a |
630 |
2 |
| Bronte Rear Outlet AG > exposed flue: can only be installed with wet back |
| pedestal & drawer base |
360 |
245 |
470 |
100 |
110 |
240 |
550 |
240 |
810 |
1295 |
1400 |
1210 |
n/a |
630 |
2 |
3 kw
wetback
|
| leg base |
360 |
245 |
405 |
100 |
110 |
240 |
550 |
240 |
810 |
1230 |
1335 |
1165 |
n/a |
630 |
2 |
| Coaster Multi Fuel |
| leg base |
100 |
275 |
300 |
110 |
100 |
230 |
595 |
420 |
860 |
905 |
1270 |
1095 |
675 |
600 |
3 |
5 or 3 kw
wetback |
| Zealandia Multi Fuel |
| leg base |
150 |
350 |
380 |
100 |
130 |
280 |
655 |
430 |
810 |
995 |
1315 |
1120 |
715 |
530 |
3 |
5 or 3 kw |